4D flow cardiovascular magnetic resonance consensus statement

J Cardiovasc Magn Reson. 2015 Aug 10;17(1):72. doi: 10.1186/s12968-015-0174-5.

Abstract

Pulsatile blood flow through the cavities of the heart and great vessels is time-varying and multidirectional. Access to all regions, phases and directions of cardiovascular flows has formerly been limited. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has enabled more comprehensive access to such flows, with typical spatial resolution of 1.5×1.5×1.5 - 3×3×3 mm(3), typical temporal resolution of 30-40 ms, and acquisition times in the order of 5 to 25 min. This consensus paper is the work of physicists, physicians and biomedical engineers, active in the development and implementation of 4D Flow CMR, who have repeatedly met to share experience and ideas. The paper aims to assist understanding of acquisition and analysis methods, and their potential clinical applications with a focus on the heart and greater vessels. We describe that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy. We also specify research and development goals that have yet to be satisfactorily achieved. Derived flow parameters, generally needing further development or validation for clinical use, include measurements of wall shear stress, pressure difference, turbulent kinetic energy, and intracardiac flow components. The dependence of measurement accuracy on acquisition parameters is considered, as are the uses of different visualization strategies for appropriate representation of time-varying multidirectional flow fields. Finally, we offer suggestions for more consistent, user-friendly implementation of 4D Flow CMR acquisition and data handling with a view to multicenter studies and more widespread adoption of the approach in routine clinical investigations.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't
  • Review

MeSH terms

  • Aorta / physiopathology
  • Blood Flow Velocity
  • Cardiovascular Diseases / diagnosis*
  • Cardiovascular Diseases / pathology
  • Cardiovascular Diseases / physiopathology
  • Cardiovascular System / pathology
  • Cardiovascular System / physiopathology*
  • Consensus
  • Coronary Circulation
  • Humans
  • Image Interpretation, Computer-Assisted / methods
  • Image Interpretation, Computer-Assisted / standards*
  • Magnetic Resonance Angiography / methods
  • Magnetic Resonance Angiography / standards*
  • Myocardial Perfusion Imaging / methods
  • Myocardial Perfusion Imaging / standards*
  • Predictive Value of Tests
  • Pulsatile Flow
  • Time Factors