Article Text

Download PDFPDF

Registry report on prediction by Pocock cardiovascular score of cerebral microemboli acutely following carotid endarterectomy
  1. Mahmud Saedon1,2,
  2. Athanasios Saratzis3,
  3. Rachel W S Lee2,
  4. Charles E Hutchinson2,
  5. Christopher H E Imray2,
  6. Donald R J Singer4,5
  1. 1 Nottingham University Hospitals NHS Trust, Nottingham, UK
  2. 2 University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
  3. 3 Leicester Royal Infirmary, Leicester, UK
  4. 4 Yale School of Medicine, New Haven, Connecticut, USA
  5. 5 Fellowship of Postgraduate Medicine, London, UK
  1. Correspondence to Professor Donald R J Singer; fpm.chandos{at}gmail.com

Abstract

Background Cerebral microemboli may lead to ischaemic neurological complications after carotid endarterectomy (CEA). The association between classical cardiovascular risk factors and acute cerebral microemboli following carotid surgery has not been studied. The aim of this study was to explore whether an established cardiovascular risk score (Pocock score) predicts the presence of cerebral microemboli acutely after CEA.

Subjects and methods Pocock scores were assessed for the 670 patients from the Carotid Surgery Registry (age 71±1 (SEM) years, 474 (71%) male, 652 (97%) Caucasian) managed from January 2002 to December 2012 in the Regional Vascular Centre at University Hospitals Coventry and Warwickshire NHS Trust, which serves a population of 950 000. CEA was undertaken in 474 (71%) patients for symptomatic carotid stenosis and in 196 (25%) asymptomatic patients during the same period. 74% of patients were hypertensive, 71% were smokers and 49% had hypercholesterolaemia.

Results A high Pocock score (≥2.3%) was significantly associated with evidence of cerebral microemboli acutely following CEA (P=0.039, Mann-Whitney (MW) test). A Pocock score (≥2.3%) did not predict patients who required additional antiplatelet therapy (microemboli signal (MES) rate >50 hour-1: P=0.164, MW test). Receiver operating characteristic analysis also showed that the Pocock score predicts acute postoperative microemboli (area under the curve (AUC) 0.546, 95% CI 0.502 to 0.590, P=0.039) but not a high rate of postoperative microemboli (MES >50 hour−1: AUC 0.546, 95% CI 0.482 to 0.610, P=0.164). A Pocock score ≥2.3% showed a sensitivity of 74% for the presence of acute postoperative cerebral microemboli. A Pocock score ≥2.3% also showed a sensitivity of 77% and a negative predictive value of 90% for patients who developed a high microembolic rate >50 hour−1 after carotid surgery.

Conclusion These findings demonstrate that the Pocock score could be used as a clinical tool to identify patients at high risk of developing acute postoperative microemboli.

  • pocock score
  • cardiovascular risk factors
  • transcranial doppler
  • microemboli
  • carotid endarterectomy

This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Contributors MS and DRJS conceived the study. All authors were responsible for the design and execution of the study. MS, AS and RWSL were responsible for data collection and data analysis. DRJS, CEH and CHEI are guarantors.

  • Competing interests None declared.

  • Ethics approval Research and Development Department at University Hospitals Coventry and Warwickshire NHS Trust.

  • Provenance and peer review Not commissioned; externally peer reviewed.

  • Data sharing statement No additional data are available.